Renesas Electronics /R7FA6M4AF /SYSC /LVD2CR0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as LVD2CR0

7 43 0 0 00 0 0 0 0 0 0 0 0 (0)RIE 0 (0)DFDIS 0 (0)CMPE 0 (00)FSAMP 0 (0)RI 0 (0)RN

FSAMP=00, RI=0, RN=0, DFDIS=0, RIE=0, CMPE=0

Description

Voltage Monitor 2 Circuit Control Register 0

Fields

RIE

Voltage Monitor 2 Interrupt/Reset Enable

0 (0): Disable

1 (1): Enable

DFDIS

Voltage monitor 2 Digital Filter Disabled Mode Select

0 (0): Enable the digital filter

1 (1): Disable the digital filter

CMPE

Voltage Monitor 2 Circuit Comparison Result Output Enable

0 (0): Disable voltage monitor 2 circuit comparison result output

1 (1): Enable voltage monitor 2 circuit comparison result output

FSAMP

Sampling Clock Select

0 (00): 1/2 LOCO frequency

1 (01): 1/4 LOCO frequency

2 (10): 1/8 LOCO frequency

3 (11): 1/16 LOCO frequency

RI

Voltage Monitor 2 Circuit Mode Select

0 (0): Generate voltage monitor 2 interrupt on Vdet2 crossing

1 (1): Enable voltage monitor 2 reset when the voltage falls to and below Vdet2

RN

Voltage Monitor 2 Reset Negate Select

0 (0): Negate after a stabilization time (tLVD2) when VCC > Vdet2 is detected

1 (1): Negate after a stabilization time (tLVD2) on assertion of the LVD2 reset

Links

() ()