FSAMP=00, RI=0, RN=0, DFDIS=0, RIE=0, CMPE=0
Voltage Monitor 2 Circuit Control Register 0
RIE | Voltage Monitor 2 Interrupt/Reset Enable 0 (0): Disable 1 (1): Enable |
DFDIS | Voltage monitor 2 Digital Filter Disabled Mode Select 0 (0): Enable the digital filter 1 (1): Disable the digital filter |
CMPE | Voltage Monitor 2 Circuit Comparison Result Output Enable 0 (0): Disable voltage monitor 2 circuit comparison result output 1 (1): Enable voltage monitor 2 circuit comparison result output |
FSAMP | Sampling Clock Select 0 (00): 1/2 LOCO frequency 1 (01): 1/4 LOCO frequency 2 (10): 1/8 LOCO frequency 3 (11): 1/16 LOCO frequency |
RI | Voltage Monitor 2 Circuit Mode Select 0 (0): Generate voltage monitor 2 interrupt on Vdet2 crossing 1 (1): Enable voltage monitor 2 reset when the voltage falls to and below Vdet2 |
RN | Voltage Monitor 2 Reset Negate Select 0 (0): Negate after a stabilization time (tLVD2) when VCC > Vdet2 is detected 1 (1): Negate after a stabilization time (tLVD2) on assertion of the LVD2 reset |